BATTERY
VOLTAGE
(11-12 VOLTS)
Indicates open in primary circuit, coil, or ground wire from coil negative terminal. Add jumper wire from coil negative terminal to ground.
READS
2.5-4.5 VOLTS
Ground wire was open. Repair or replace.
STAYS AT
11-12 VOLTS
Coil is open. Replace coil.
Choose one of the following: